Hardware Tour

Let's start this manual with a short tour of a Fluksometer's externals. We will in turn introduce the Fluksometer's ports, buttons and LEDs.

The Fluksometer v3 is currently available in a single 'E' version, a.k.a. FLM03E.

Ports

The screw terminal contains fourteen inputs. A port on the screw terminal is defined as a pair of adjacent inputs. The port numbers are printed on the front of the enclosure for easy reference, with the polarity denoted by + and -. Ports #1 to #3 are current clamp ports that are tuned to accept Flukso FLS06-type split-core current clamps. Ports #4, #5 and #6 can be used for counting pulses. This includes support for the S0 interface (S0 is an open-collector interface standardized in DIN EN 62053-31) common to DIN-rail energy meters. Pulse ports accept Flukso water and gas probes as well. Port #7 can be hooked up to a NTA8130-compliant local P1 port found on Dutch smart meters. Contrary to the other ports, port #7 has its polarity indicated by the letters a and b.

Note: The current FLM03E firmware still lacks the P1 port decoder. This functionality will be added in a future release.

Ethernet

Both ethernet ports support a 10baseT/100baseTx interface with auto-negotiation and auto MDI/MDI-X crossover detection. The right ethernet port (LAN) is meant for configuring the Fluksometer, while the left port (WAN) can be used for connecting the FLuksometer with the internet. In other words, the WAN port is the uplink, the LAN port the downlink.

Power Jack

While the power port can still accepts a 9-15V DC voltage, we now ship all Fluksometer v3's with a 9V AC-AC adapter. The AC adapter acts as a power source to the FLM03 as well as the line voltage sensor.

Pushbutton

The pushbutton has a dual function. Which function will be triggered depends on how long the button is pressed. Make sure the heartbeat LED is blinking before using the button.

Mode Description
Restore networking defaults If you press the button between 2 and 5 seconds, the Fluksometer will restore its default network settings.
Restore firmware Keep the button pressed for between 10 and 15 seconds to restore the Fluksometer's stock firmware and reboot. You will have to reconfigure all network and sensor settings. Connect to the local web interface after the heartbeat LED starts blinking again.

LEDs

The Fluksometer has six red LEDs on the top of its enclosure. Together these LEDs provide an overview of the Fluksometer's internal functioning, the status of its network interfaces and its ability to communicate with the Flukso server. From left to right, these LEDs are:

LED Description
Wifi If the wifi interface is enabled and the Fluksometer can successfully connect to the wireless network, the wifi LED will be on. Network traffic will cause the LED to blink.
Ethernet The ethernet LEDs will be on when their respective ethernet links are established. This can either be a 10baseT or 100baseTX link in full- or half-duplex mode. The left ethernet LED maps to the WAN interface, the right one to the LAN.
Globe After the Fluksometer has finished its boot sequence, the globe LED will be on when it can access the Flukso server via MQTT. The MQTT connection is configured with a restart timeout of 30 seconds. There might thus be a slight delay between a successful network configuration and the globe LED lighting up.
Heartbeat The heartbeat LED is positioned right next to the globe LED. While the globe LED informs us about the status of the Fluksometer's external communication, the heartbeat LED allows us to monitor the Fluksometer's internal functioning. This LED will be on when the sensor board is running its firmware. From the moment the daemon is started during the boot sequence, it will continuously send a 'ping' to the sensor board every second. Each poll triggers a double-blink of this LED, thus mimicking a real heartbeat. Hence, a 'heartbeat' is an indication of a Fluksometer that has booted, a running daemon, a sensor board running its firmware and proper communication between the main board and sensor board.
Power The power LED is directly connected to the internal 3.3V supply. A burning LED indicates that power has been applied to the device and the internal voltage regulators are working properly.